FAST HIGH VOLTAGE SOLID-STATE SWITCHES |
|
E |
Fast Recovery High Voltage Diode Assemblies▶ |
|
● Free wheeling diodes for HTS solid-state switches in combination with inductive load ● Soft recovery characteristics ● High peak current capability ● Short recovery time |
|
Model [sorted by |
Description / Comment |
Dimensions |
Voltage |
Pk. Current |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FDA 60-180 |
● |
Especially for HTS 61-40, HTS 61-240-SI and 61-160-FI |
78 x 76 x 25 |
6 |
1800 |
|
FDA 60-240 |
● |
Especially for HTS 61-40, HTS 61-240-SI and 61-160-FI |
102 x 76 x 25 |
6 |
2400 |
|
|
|
|
|
|
|
|
● |
|
84 x 35 x 30 |
10 |
750 |
|
|
● |
|
84 x 35 x 30 |
10 |
1500 |
|
|
● |
|
84 x 35 x 30 |
16 |
750 |
|
|
● |
|
84 x 35 x 30 |
16 |
1500 |
|
|
|
|
|
|
|
|
|
● |
|
101 x 35 x 30 |
20 |
750 |
|
|
● |
|
101 x 35 x 30 |
20 |
1500 |
|
|
|
|
|
|
|
|
|
● |
|
116 x 35 x 30 |
24 |
750 |
|
|
● |
|
116 x 35 x 30 |
24 |
1500 |
|
|
|
|
|
|
|
|
|
● |
|
141 x 35 x 30 |
30 |
750 |
|
|
● |
|
141 x 35 x 30 |
30 |
1500 |
|
|
|
|
|
|
|
|
|
● |
|
152 x 35 x 30 |
32 |
750 |
|
|
● |
|
152 x 35 x 30 |
32 |
1500 |
|
|
|
|
|
|
|
|
|
FDA 640-75 |
● |
|
300 x 35 x 35 |
64 |
750 |
|
FDA 640-150 |
● |
|
300 x 53 x 53 |
64 |
1500 |
|
|
|
|
|
|
|
|
FDA 800-75 |
● |
|
400 x 35 x 35 |
80 |
750 |
|
FDA 800-150 |
● |
|
400 x 53 x 53 |
80 |
1500 |
|
|
|
|
|
|
|
|
FDA 100-300 |
● |
|
84 x 70 x 35 |
16 |
3000 |
|
|
|
|
|
|
|
|
FDA 160-300 |
● |
|
103 x 70 x 35 |
16 |
3000 |
|
|
|
|
|
|
|
|
FDA 200-300 |
● |
|
103 x 70 x 35 |
20 |
3000 |
|
|
|
|
|
|
|
|
FDA 240-300 |
● |
|
116 x 70 x 35 |
24 |
3000 |
|
|
|
|
|
|
|
|
FDA 320-300 |
● |
|
152 x 70 x 35 |
32 |
3000 |
|
|
|
|
|
|
|
|
FDA 640-300 |
● |
|
300 x 70 x 35 |
64 |
3000 |
|
|
|
|
|
|
|
|
FDA 800-300 |
● |
|
370 x 70 x 35 |
80 |
3000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Option(1) |
Description |
|
|
|
|
PT-HV |
Pigtails for HV Connection: Flexible leads with cable lugs. Not recommended in extremely fast circuits. |
|
UL94 |
Flame Retardant Casting Resin: Casting resin according to UL-94-VO. Minimum order quantity required. (2) |
|
ITC |
Increased Thermal Conductivity: Special moulding process to increase the thermal conductivity of the module. Pd(max) will be increased by approx. 20-30%. (2) |
|
CF |
Non-Isolated Cooling Fins: Standard sizes in categories I to VII according to model. Nickel plated copper 0.5 mm, fin height 35 mm. For air and liquid cooling (e.g. Galden® or oil). |
|
CF-1 |
Non-Isolated Cooling Fins d=1mm: Nickel plated copper 1.0 mm instead of 0.5 mm. The Max. Power Dissipation will be increased by ~80 %. For air and liquid cooling (e.g. Galden® or oil). |
|
CF-X2 |
Non-Isolated Cooling Fins enlarged by x2: Fin area enlarged by factor 2. Not relevant in connection with liquid cooling. |
|
CF-X3 |
Non-Isolated Cooling Fins enlarged by x3: Fin area enlarged by factor 3. Not relevant in connection with liquid cooling and forced air convection. |
|
CF-CS |
Non-Isolated Cooling Fins with customized shape: Individual shape to meet specific OEM requirements. (2) |
|
CF-LC |
Non-isolated Cooling Fins optimized for liquid cooling: Double fins, nickel plated copper, 0.5 mm thickness, height 20 mm. |
|
GCF |
Grounded Cooling Flange: Cooling by a grounded base plate made of nickel plated copper. For high power applications. Increased coupling capacitance. Isolation voltage up to 40 kVDC. |
|
GCF-X2 |
Grounded Cooling Flange, Max. Continuous Power Dissipation increased by x2: Thermal resistance Switch to Flange reduced for twice the power capability. (2) |
|
GCF-W |
Water Cooler for Grounded Cooling Flange: Flat water cooling plate attached to the grounded cooling flange GCF. With water inlet and outlet. |
|
DLC |
Direct Liquid Cooling: Internal liquid channel in direct contact with the power semiconductors. Very compact cooling solution for medium power. Galden® and non-conductive liquids only. (2) |
|
HI-REL |
High Reliability / MIL Versions: Available on request. (2) |
|
|
|
|
(1) New option code: Data sheets may differ from this coding system (especially older ones) and do not indicate all possible options as per above table. (2) Please consult factory for detailed information. |
|
|
|
|
|
Further information, data sheets and drawings are available on request. All data and specifications subject to change without notice. BEHLKE POWER ELECTRONICS GmbH June 2009 |
|